Found 271 results in 0 milliseconds.

Page

Optional accessories

Optional accessories for lexsyg research Sample cups/discs Learn more Aliquot preparation kit Learn more LED head lamp Learn more Vacuum pump Compact rotary vane pump, Automatically controlled by the lexsyg device , Low weight, Low maintenance, Includes all necessary seals, flanges and pipes, Learn more Air compressor Learn more

Page

Air compressor

Skip breadcrumb navigation Breadcrumb Freiberg Instruments Products Luminescence Dating and Dosimetry lexsygresearch Optional accessories Air compressor Air compressor Low noise and portable air compressor for all lexsyg devices Interested? Get in touch! Contact now Maximum pressure: 8 bars Low noise (33 dB) Weight (22 kg)

Page

PMT detection unit

Skip breadcrumb navigation Breadcrumb Freiberg Instruments Products Luminescence Dating and Dosimetry lexsygresearch Configuration options PMT detection unit PMT detection unit High-precision detection for groundbreaking analysis results Interested? Get in touch! Contact now Standard UV-VIS PMT unit (300 – 650 nm) Standard UV-VIS PMT unit (280 – 650 nm) standard detection unit for application in luminescence dating and dosimetry bi-alkaline cathode PMT (HAMAMATSU H7360-02) sensitivity range: 300-650 nm peak sensitivity: 420 nm ( 3.1 E5 counts s -1 pW -1 ) dark counts typ. <100 cts photon counter counting linearity (random pulses, 10% loss) 6.0 E6 cps UV-VIS optics Standard UV-VIS PMT unit (280 - 650 nm) Extended UV-VIS PMT unit (160 – 630 nm) for standard applications in luminescence dating and dosimetry detection unit with standard bi-alkaline cathode PMT (Electron Tubes 9235QB) sensitivity 160-630 nm peak sensitivity: 30% quantum efficiency @ 200 nm and 350 nm dark count typ. 300 cts photon counter counting linearity (random pulses, 10% loss) UV-VIS optics Red enhanced UV-VIS PMT unit (300 – 720 nm) Red enhanced UV-VIS PMT unit (300 – 720 nm) necessary/useful if standard UV-VIS PMT sensitivity in the yellow to red wavelength band is insufficient useful e.g. for quartz (flint)/calcite orange-red or feldspar red luminescence measurements thermoelectric/air cooled GaAsP photocathode PMT (HAMAMATSU) sensitivity: 300 – 720 nm peak-sensitivity: 40% quantum efficiency @ 580 nm cooling max. 35 °C below room temperature cooling time approx. 5 min typically 100 cps dark signal at 0°C photon counting system counting linearity (random pulses, 10% count loss) 1.5 E6 cps UV-VIS optics Red enhanced UV-VIS PMT unit (300 - 720 nm) VIS-NIR PMT unit (380 – 890 nm) VIS-NIR PMT unit (380 – 890 nm) required for RF dose determination employing the 865 nm potassium feldspar emission required for 880 nm IRPL detection useful/necessary for any other measurements where red and NIR sensitivity is needed thermoelectric/air cooled GaAs photocathode PMT (HAMAMATSU H7421-50) sensitivity: 380 – 890 nm, peak-sensitivity: 12% quantum efficiency @ 800 nm cooling max. 35 °C below room temperature cooling time approx. 5 min typically 60 cps dark signal at -10°C (125 cps at 0°C) photon counting system counting linearity (random pulses, 10% count loss) 1.5 E6 cps includes UV-NIR optics VIS-NIR PMT unit (380 -890 nm)

Page

Irradiation sources

Skip breadcrumb navigation Breadcrumb Freiberg Instruments Products Luminescence Dating and Dosimetry lexsygresearch Configuration options Irradiation sources Irradiation sources for irradiations from room temperature up to 500 °C Interested? Get in touch! Contact now The lexsyg TL/OSL reader can be equipped with up to 2 irradiation units. A sensor controlled mechanical shutter moved by air pressure provides repeatable, easy and safe functionality. Beta source radioisotope: Sr-90; activity: 1.85 GBq; dose rate: about 0.11 Gy/s dose rate variation over the irradiation area: ≤ (± 10 %) @ 8 mm diameter, ≤ (± 12.5 %) @ 10 m diameter maximum energy: ca. 2.2 MeV Beta irradiation unit Beta source (ring) radioisotope: Sr-90; activity: < 3 GBq; dose rate: about 0.06 Gy/s very homogeneous dose rate over the irradiation area: (± 2.5 %) @ 8 mm diameter; (± 3.5 %) @ 10 mm diameter maximum energy: ca. 2.2 MeV required for Radio Fluorescence (RF) measurements/applications Alpha source Alpha irradiation unit radioisotope: Am-241, activity: 20- 30 MBq cover layer: ~3 μm Au active diameter: 21.0 mm (thickness 0.25mm) alpha type of radiation maximum Energy: 5.5 MeV very homogeneous dose rate over irradiation area Alpha irradiation unit X-ray generator X-ray generator - an alternative to beta/alpha source variable dose rate in contrast to beta/alpha source fully housed X-ray tube for highly homogeneous irradiation fully integrated dose rate live-time monitoring system zero radiation (when not in use) Technical details target material: Tungsten tube current: 0.1 - 1.0 mA maxmimum voltage: 50 kV shutter: 5 mm brass absorber: Al, 200 µm (changeable) varian VF-50J (fully housed)

Page

Pulsed OSL (10 µs)

Skip breadcrumb navigation Breadcrumb Freiberg Instruments Products Luminescence Dating and Dosimetry lexsygresearch Configuration options Pulsed OSL (10 µs) Pulsed OSL (10 µs) Maximum power, homogeneity and stability provided by the interchangeable OSL unit Interested? Get in touch! Contact now All lexsyg smart and lexsygresearch TL/OSL readers can be equipped with an interchangeable OSL unit containing up to three stimulation wavelengths. These are provided by high power stimulation LEDs or laser diodes. The integration of photo diodes provides the feedback for power control of each individual element, guaranteeing a stable stimulation source, independent of element aging. LED/laser diodes stimulation Available stimulation wavelengths: (LED/laser diodes) UV (365 nm), Violet (405 nm), Blue (458 nm), Green (525 nm), Yellow (590 nm), IR (850 nm), Red (620 nm) Modes of operation for OSL Continuous Wave OSL (CW-OSL) Linear Modulated OSL (LM-OSL) Pulsed OSL (POSL) Select up to three wavelengths per OSL unit: LED stimulations: Module# L0403 – Blue LED stimulation 458 ± 5 nm (max. 100 mW/cm² at sample position) Module# L0404 – IR LED stimulation 850 ± 20 nm (max. 300 mW/cm² at sample position) Module# L0405 – Green LED stimulation 525 ± 20 nm (max. 80 mW/cm² at sample position) Module# L0410 – VioletLED stimulation 405 ± 3 nm (max. 100 mW/cm² at sample position) Module# L0411 – UV LED stimulation 365 ± 3 nm (max. 100 mW/cm² at sample position); for bleaching Module# L0419 – Red LED stimulation (~620 nm) Laser diode stimulation: Rise/fall time: < 10 ns ON-Time: 50 ns to continuous wave Module# L0407 – Blue laser diode stimulation 445 ± 3 nm (max. 100 mW/cm² at sample position) Module# L0408 – IR laser diode stimulation 850 ± 3 nm (max. 300 mW/cm² at sample position) Module# L0409 – Violet laser diode stimulation 405 ± 3 nm (max. 100 mW/cm² at sample position) Module# L50064 – Green laser diode stimulation 523 ± 8 nm (max. 50 mW/cm² at sample position) Module# L50065 – Red laser diode stimulation 638 ± 5 nm (max. 75 mW/cm² at sample positio

Page

Filter wheel

Skip breadcrumb navigation Breadcrumb Freiberg Instruments Products Luminescence Dating and Dosimetry lexsygresearch Configuration options Filter wheel Filter wheel including suitable filters Interested? Get in touch! Contact now Filter wheel including suitable filters, which are optimized for maximized luminescence light collection and maximum suppression of scattered light (OSL, PL) and thermal noise (TL), recommended as minimum configuration to perform optimized TL/OSL/RF analyses in dating and other applications. Optics designed for high-efficiency light collection for PMT luminescence measurements Programmable change of detection window (duration of filter change between 300 ms and maximum 3s) during measurement Filter choice is software restricted according the chosen stimulationwavelength, thus malfunction (over exposure) is prevented Malfunctions are software protected, including PMT damage protection during measurement Optimized filter-sets for all main quartz or feldspar mineral luminescence emissions and for other materials/applications are available Filter sets (interference, color-glass optical filters) optimized for largest transmission of individual wavelength bands and best blocking of stimulation light (OSL) and/or thermal noise (TL, blackbody radiation) A filter wheel has 6 position and each position up to 6.5 mm of stacked filter thickness. 15 measurement functions are included (more information are available on request)

Page

InfraRedPhotoLuminescence (IRPL)

Skip breadcrumb navigation Breadcrumb Freiberg Instruments Products Luminescence Dating and Dosimetry lexsygresearch Configuration options InfraRedPhotoLuminescence (IRPL) InfraRedPhotoLuminescence (IRPL) allows very precise measurements due to the non-destructive nature of the measurement Interested? Get in touch! Contact now Compared to the standard IRSL the IRPL signal from K-feldspar is considered as probably being not, but certainly much less affected by fading (Prasad et. al., 2017). It also exhibits a larger dose range, thus allowing the dating of old samples. The required pulsed stimulation and detection of both emissions (880 and 955 nm) is implemented into l exsyg TL/OSL reader , which allows very precise measurements due to the non-destructive nature of the measurement. However, not all samples appear to show a 955 nm emssion and detection at 880 nm might be sufficient. Prasad, A. K., Poolton, N. R. J., Kook, M., and Jain, M. (2017). Optical dating in a new light: A direct, non-destructive probe of trapped electrons. Scientific Reports 7, 12097, 10.1038/s41598-017-10174-8.

Page

Thermal stimulation

Skip breadcrumb navigation Breadcrumb Freiberg Instruments Products Luminescence Dating and Dosimetry lexsygresearch Configuration options Thermal stimulation Thermal stimulation Thermal stimulation up to 710 °C, allowing user-defined heating and cooling cycles for TL, preheating and elevated temperature OSL Interested? Get in touch! Contact now Ceramic heating element allows highly reliable and more consistent measurements. The heating element is cooled by continuous flow of nitrogen or compressed air. Thermoluminescence (TL), preheat (PH) including elevated temperature luminescence measurements (OSL, RL, etc.) as well as elevated temperature irradiation (at ionizing irradiation and “solar-light” position) are possible during any part of a heating/cooling cycle, which is almost freely programmable including non-linear heating/cooling functions. Heating rate: 0.1 - 20.0 C/s (@Tmax= up to 710 °C) Highly flexible step-wise programming of heating / cooling cycles within system parameters (i.e. temperature and heating/cooling rates) Software options for further temperature control (e.g. non-linear functions)

Page

Red stimulated quartz OSL

Skip breadcrumb navigation Breadcrumb Freiberg Instruments Products Luminescence Dating and Dosimetry lexsygresearch Configuration options Red stimulated quartz OSL Red stimulated quartz OSL allows a separation of the fast OSL component in thermally optically stimulated (TM-OSL) mode Interested? Get in touch! Contact now Following Chruścińska et.al. (2018) and Palczewski & Chruścińska (2019) the stimulation of quartz at 620 nm allows a separation of the fast OSL component in thermally optically stimulated (TM-OSL) mode. Red OSL at 620 nm is now available for lexsyg TL/OSL reader . Chruścińska, A., Szramowski, A., Thermally modulated OSL related to the fast component of the OSL signal in quartz, Radiat. Meas. 120, (2018), 20-25. Palczewski P & Chruścińska A (2019) Different components of the quartz OSL signal resolved by the TM-OSL method. Radiation Measurements 121, 32-36.

Page

Peltier cooling

Skip breadcrumb navigation Breadcrumb Freiberg Instruments Products Luminescence Dating and Dosimetry lexsygresearch Configuration options Peltier cooling Peltier cooling for radiation defect characterization Interested? Get in touch! Contact now Low temperature conditions are used for radiation defect characterization. The system is capable of providing stable sample temperatures from -40 °C to -50 °C, while an automated change for high temperature conditions is achieved within seconds, which allows heating up to 710 °C. Min temperature: about -50 °C recommended min temp: -40 °C -40 °C can be kept stable > 60 minutes cooling can be combined with irradiation, OSL, TL, RF, Solar simulation Note: Peltier cooling unit requires vacuum pump and Nitrogen atmosphere