Found 271 results in 1 milliseconds.

Page

Pulsed OSL (10 µs)

Skip breadcrumb navigation Breadcrumb Freiberg Instruments Products Luminescence Dating and Dosimetry lexsygresearch Configuration options Pulsed OSL (10 µs) Pulsed OSL (10 µs) Maximum power, homogeneity and stability provided by the interchangeable OSL unit Interested? Get in touch! Contact now All lexsyg smart and lexsygresearch TL/OSL readers can be equipped with an interchangeable OSL unit containing up to three stimulation wavelengths. These are provided by high power stimulation LEDs or laser diodes. The integration of photo diodes provides the feedback for power control of each individual element, guaranteeing a stable stimulation source, independent of element aging. LED/laser diodes stimulation Available stimulation wavelengths: (LED/laser diodes) UV (365 nm), Violet (405 nm), Blue (458 nm), Green (525 nm), Yellow (590 nm), IR (850 nm), Red (620 nm) Modes of operation for OSL Continuous Wave OSL (CW-OSL) Linear Modulated OSL (LM-OSL) Pulsed OSL (POSL) Select up to three wavelengths per OSL unit: LED stimulations: Module# L0403 – Blue LED stimulation 458 ± 5 nm (max. 100 mW/cm² at sample position) Module# L0404 – IR LED stimulation 850 ± 20 nm (max. 300 mW/cm² at sample position) Module# L0405 – Green LED stimulation 525 ± 20 nm (max. 80 mW/cm² at sample position) Module# L0410 – VioletLED stimulation 405 ± 3 nm (max. 100 mW/cm² at sample position) Module# L0411 – UV LED stimulation 365 ± 3 nm (max. 100 mW/cm² at sample position); for bleaching Module# L0419 – Red LED stimulation (~620 nm) Laser diode stimulation: Rise/fall time: < 10 ns ON-Time: 50 ns to continuous wave Module# L0407 – Blue laser diode stimulation 445 ± 3 nm (max. 100 mW/cm² at sample position) Module# L0408 – IR laser diode stimulation 850 ± 3 nm (max. 300 mW/cm² at sample position) Module# L0409 – Violet laser diode stimulation 405 ± 3 nm (max. 100 mW/cm² at sample position) Module# L50064 – Green laser diode stimulation 523 ± 8 nm (max. 50 mW/cm² at sample position) Module# L50065 – Red laser diode stimulation 638 ± 5 nm (max. 75 mW/cm² at sample positio

Page

Red stimulated quartz OSL

Skip breadcrumb navigation Breadcrumb Freiberg Instruments Products Luminescence Dating and Dosimetry lexsygresearch Configuration options Red stimulated quartz OSL Red stimulated quartz OSL allows a separation of the fast OSL component in thermally optically stimulated (TM-OSL) mode Interested? Get in touch! Contact now Following Chruścińska et.al. (2018) and Palczewski & Chruścińska (2019) the stimulation of quartz at 620 nm allows a separation of the fast OSL component in thermally optically stimulated (TM-OSL) mode. Red OSL at 620 nm is now available for lexsyg TL/OSL reader . Chruścińska, A., Szramowski, A., Thermally modulated OSL related to the fast component of the OSL signal in quartz, Radiat. Meas. 120, (2018), 20-25. Palczewski P & Chruścińska A (2019) Different components of the quartz OSL signal resolved by the TM-OSL method. Radiation Measurements 121, 32-36.

Page

Filter wheel

Skip breadcrumb navigation Breadcrumb Freiberg Instruments Products Luminescence Dating and Dosimetry lexsygresearch Configuration options Filter wheel Filter wheel including suitable filters Interested? Get in touch! Contact now Filter wheel including suitable filters, which are optimized for maximized luminescence light collection and maximum suppression of scattered light (OSL, PL) and thermal noise (TL), recommended as minimum configuration to perform optimized TL/OSL/RF analyses in dating and other applications. Optics designed for high-efficiency light collection for PMT luminescence measurements Programmable change of detection window (duration of filter change between 300 ms and maximum 3s) during measurement Filter choice is software restricted according the chosen stimulationwavelength, thus malfunction (over exposure) is prevented Malfunctions are software protected, including PMT damage protection during measurement Optimized filter-sets for all main quartz or feldspar mineral luminescence emissions and for other materials/applications are available Filter sets (interference, color-glass optical filters) optimized for largest transmission of individual wavelength bands and best blocking of stimulation light (OSL) and/or thermal noise (TL, blackbody radiation) A filter wheel has 6 position and each position up to 6.5 mm of stacked filter thickness. 15 measurement functions are included (more information are available on request)

Page

PMT detection unit

Skip breadcrumb navigation Breadcrumb Freiberg Instruments Products Luminescence Dating and Dosimetry lexsygresearch Configuration options PMT detection unit PMT detection unit High-precision detection for groundbreaking analysis results Interested? Get in touch! Contact now Standard UV-VIS PMT unit (300 – 650 nm) Standard UV-VIS PMT unit (280 – 650 nm) standard detection unit for application in luminescence dating and dosimetry bi-alkaline cathode PMT (HAMAMATSU H7360-02) sensitivity range: 300-650 nm peak sensitivity: 420 nm ( 3.1 E5 counts s -1 pW -1 ) dark counts typ. <100 cts photon counter counting linearity (random pulses, 10% loss) 6.0 E6 cps UV-VIS optics Standard UV-VIS PMT unit (280 - 650 nm) Extended UV-VIS PMT unit (160 – 630 nm) for standard applications in luminescence dating and dosimetry detection unit with standard bi-alkaline cathode PMT (Electron Tubes 9235QB) sensitivity 160-630 nm peak sensitivity: 30% quantum efficiency @ 200 nm and 350 nm dark count typ. 300 cts photon counter counting linearity (random pulses, 10% loss) UV-VIS optics Red enhanced UV-VIS PMT unit (300 – 720 nm) Red enhanced UV-VIS PMT unit (300 – 720 nm) necessary/useful if standard UV-VIS PMT sensitivity in the yellow to red wavelength band is insufficient useful e.g. for quartz (flint)/calcite orange-red or feldspar red luminescence measurements thermoelectric/air cooled GaAsP photocathode PMT (HAMAMATSU) sensitivity: 300 – 720 nm peak-sensitivity: 40% quantum efficiency @ 580 nm cooling max. 35 °C below room temperature cooling time approx. 5 min typically 100 cps dark signal at 0°C photon counting system counting linearity (random pulses, 10% count loss) 1.5 E6 cps UV-VIS optics Red enhanced UV-VIS PMT unit (300 - 720 nm) VIS-NIR PMT unit (380 – 890 nm) VIS-NIR PMT unit (380 – 890 nm) required for RF dose determination employing the 865 nm potassium feldspar emission required for 880 nm IRPL detection useful/necessary for any other measurements where red and NIR sensitivity is needed thermoelectric/air cooled GaAs photocathode PMT (HAMAMATSU H7421-50) sensitivity: 380 – 890 nm, peak-sensitivity: 12% quantum efficiency @ 800 nm cooling max. 35 °C below room temperature cooling time approx. 5 min typically 60 cps dark signal at -10°C (125 cps at 0°C) photon counting system counting linearity (random pulses, 10% count loss) 1.5 E6 cps includes UV-NIR optics VIS-NIR PMT unit (380 -890 nm)

Page

InfraRedPhotoLuminescence (IRPL)

Skip breadcrumb navigation Breadcrumb Freiberg Instruments Products Luminescence Dating and Dosimetry lexsygresearch Configuration options InfraRedPhotoLuminescence (IRPL) InfraRedPhotoLuminescence (IRPL) allows very precise measurements due to the non-destructive nature of the measurement Interested? Get in touch! Contact now Compared to the standard IRSL the IRPL signal from K-feldspar is considered as probably being not, but certainly much less affected by fading (Prasad et. al., 2017). It also exhibits a larger dose range, thus allowing the dating of old samples. The required pulsed stimulation and detection of both emissions (880 and 955 nm) is implemented into l exsyg TL/OSL reader , which allows very precise measurements due to the non-destructive nature of the measurement. However, not all samples appear to show a 955 nm emssion and detection at 880 nm might be sufficient. Prasad, A. K., Poolton, N. R. J., Kook, M., and Jain, M. (2017). Optical dating in a new light: A direct, non-destructive probe of trapped electrons. Scientific Reports 7, 12097, 10.1038/s41598-017-10174-8.

Page

X-ray Fluorescence (XRF)

Skip breadcrumb navigation Breadcrumb Freiberg Instruments Products Luminescence Dating and Dosimetry lexsygresearch Configuration options X-ray Fluorescence (XRF) X-ray Fluorescence (XRF) This module allows an estimate of the mineral composition of feldspar samples. The relative proportion of K-/Na/-Ca-feldspar is estimated as well as the possible quartz contamination. Interested? Get in touch! Contact now This module allows an estimate of the mineral composition of feldspar samples. The relative proportion of K-/Na/-Ca-feldspar is estimated as well as the possible quartz contamination. The XRF unit consist of: Amptek X-123 complete spectrometer with SDD Complete X-ray spectrometer Amptek MINI-X USB controlled X-ray tube Software extension for XRF analysis: A special program for analyzing the XRF data for conversion of the result onto the ternary diagram of K-/Na/-Ca-feldspar and providing an estimate of quartz contamination. Reference samples for performing and maintaining the K-/Na/-Ca-feldspar calibration are included. Special sample cups: Sample cups specially made from molybdenum metal (200 pieces will be supplied) Note: XRF unit requires vacuum pump.

Page

EMCCD

Skip breadcrumb navigation Breadcrumb Freiberg Instruments Products Luminescence Dating and Dosimetry lexsygresearch Configuration options EMCCD EMCCD Dose determination of single grains on multi grain aliquots by spatially resolved luminescence provided by a state-of-the-art electron multiplying CCD camera (EMCCD) Interested? Get in touch! Contact now Spatially Resolved Single Grain Analysis using EMCCD UV to NIR (200 – 1050 nm) image detection for spatially resolved / single-grain measurement operational at the TL/OSL or RF measurement position 512 x 512 pixel back-thinned, UV-coated EMCCD chip (electron multiplying – EM - technology), 16 bit resolution, frame – transfer format operates also in traditional CCD mode (low noise) max. frame rate: > 33 frames/second (full frame) gigabit Ethernet data interface high quantum efficiency from UV to NIR : approx. 50% @ UV Quartz OSL emission peak; approx. 85-90 % @ all VIS Quartz/Feldspar emission peaks; approx. 60% @ potassium feldspar NIR RF peak (865 nm) ~8 mm diameter sample is imaged on the camera chip (ca. 16 μm / pixel) incl. electromechanical shutter TE cooling min. -95 °C (-70 °C guaranteed for life), thermostatic precision ± 0.05°C integration into lexsyg measurement control software

Page

Sample camera

Skip breadcrumb navigation Breadcrumb Freiberg Instruments Products Luminescence Dating and Dosimetry lexsygresearch Configuration options Sample camera Sample camera The sample camera is designed to automatically record the appearance of the sample after luminescence measurements. Interested? Get in touch! Contact now The sample camera is designed to automatically record the appearance of the sample after luminescence measurements. For example: Visual inspection after luminescence data collection Use of image analysis for determining e.g. number of grains, coverage area, grain size distribution, color distribution The camera is mounted in a mechanical fixture that is vacuum tight, light tight and holds a diffuse light illumination system to assure proper white light illumination of the sample that is photographed. Technical details of the camera: TheImagingSource 1/2.5 “Micron CMOS 5Mp camera or similar camera (example: DFM 72BUC02-ML) Computar 3Mp f=25mm lens

Page

Spectrometry detection unit

Skip breadcrumb navigation Breadcrumb Freiberg Instruments Products Luminescence Dating and Dosimetry lexsygresearch Configuration options Spectrometry detection unit Spectrometry detection unit for IR and UV spectroscopy Interested? Get in touch! Contact now OE-CCD based high sensitivity spectrometry detection unit (Recommended for IR spectroscopy) fiber-coupled CCD based luminescence emission spectrometer TE-cooled (min. -80 °C) CCD-detector 200 – 1050 nm, 16 bit digitization easy change of gratings and wavelength re-calibration, one grating can be selected powerful spectrometry software integration into lexsyg measurement control software BU-CCD based high sensitivity spectrometry detection unit (Recommended for UV spectroscopy) 1024 x 255 Pixel, 26 μm back Illuminated BU 5 years guarantee of UltraVac vacuum sealing of CCD-chamber including software implementation high quality Non-Imaging spectrograph focal distance: 163 mm aperture ratio: 3.6 grate: 300 l/mm, Blaze 500 nm optical fiber: Custom fiber bundle UV-VIS, Overall length: 3 m +/-5 cm, Fiber count: 114 approx. adapter for manual gap and shutter flange with cylindrical lens for InGaAs-Detector variable gap for SR163: 10 μm-13 mm

Page

Bleaching/Solar simulation unit

Skip breadcrumb navigation Breadcrumb Freiberg Instruments Products Luminescence Dating and Dosimetry lexsygresearch Configuration options Bleaching/Solar simulation unit Bleaching/Solar simulation unit for monochromatic sample irradiation or individually mixed for simulation of various bleaching conditions Interested? Get in touch! Contact now Features power LED-array based light irradiator, fan-cooled fully software controlled (power, irradiation time, mixing ratios - if applicable) within a measurement sequence the settings can be varied special optics for uniform irradiation power at the sample bleaching is possible at elevated temperatures LED-based bleaching/Solar simulation unit wavelengths: 365 nm, 462 nm, 523 nm, 590 nm, 625nm, 850 nm can be used for monochromatic sample irradiation or individually mixed for simulation of variousbleaching conditions typical maximum optical power at the sample: UV 365 nm : 65 mW RGB A 462 nm : 140 mW, 523 nm : 35 mW, 590 nm : 50 mW, 625 nm : 85 mW; IR 850 nm: 170 mW power regulation loop for each light channel display of bleaching light spectrum