Found 271 results in 3 milliseconds.

Application

Single grain/spatially resolved luminescence dating

Spatially resolved luminescence Single grain dating for mixed sediments or heterogenous radiation fields Not every grain in a sediment sample reflects the same last bleaching and burial history. By analysing single mineral entities (whether grains or parts of it) different dose populations can be distinguished and models derived for different events of e.g. beaching or deposition. Single grain detection through spatially resolved luminescence Measurement of single grains Detection of bioturbation and mixing Differentiation of sedimentation components, like rock erosion versus aeolian Spatial analysis of heterogeneous samples, e.g. with mineral intergrowth Related topic: Unheated rock surfaces Chauhan N, Adhyaru P, Vaghela H & Singhvi AK (2014) EMCCD based luminescence imaging system for spatially resolved geo-chronometric and radiation dosimetric applications. Journal of Instrumentation 9, P11016. Greilich S & Wagner GA (2006) Development of a spatially resolved dating technique using HR-OSL. Radiation Measurements 41, 738-743. Olko P, Czopyk L, Klosowski M & Waligórski MPR (2008) Thermoluminescence dosimetry using TL-readers equipped with CCD cameras. Radiation Measurements 43, 864-869. False colour spatially resolved luminescence of the first 2 seconds of blue stimulated luminescence from quartz grains, detected with a lexsyg research Matching Products TL/OSL series lexsygresearch The most advanced TL/OSL reader Learn more Get in touch Do not hesitate to contact us – we are available to assist you with any inquiries or requests. Use our inquiry tool or reach out via email: sales @ freiberginstruments.com

Product

SmartKONT

Skip breadcrumb navigation Breadcrumb Freiberg Instruments Products Radiation Monitoring Systems SmartKONT SmartKONT Radiation contamination monitor Interested? Get in touch! Contact now Skip menu Quick navigation Features Software Contact Features & Benefits Measuring device for the connection of beta + alpha or alpha sensitive proportional detectors, such as HGZ / RGZ 200-T. Measurement results with decision aids conforming to DIN ISO 11929. rugged aluminium housing with 7“ colour display (resolution 800 x 480 pixels) and touch functions SMC 2100 measuring technique proven in use with serial RS 485 interface for PC connection switchable loudly puIse acoustic, headphone jack storage of measurement results on Micro SD card readout of measurement values via USB connection mains or battery pack operation, accumulator charging during mains operation energy management for battery pack monitoring external Start and Storage button, release via. infrared or cable button Interested? Our experts are happy to assist you. Get in touch! Contact us now! Software detection of the results DIN ISO 11929 conform contamination or release measurements automatic determination of requested measuring time single measurement or rate meter Alpha+Beta and Alpha measurements displayed results cps or Bq/cm2 selectable recurrent examination support storage of measuring values with comments device, measurement and calibration parameters free selectable Windows software AM-SMCA01 Get in touch Do not hesitate to contact us – we are available to assist you with any inquiries or requests. Use our inquiry tool or reach out via email: sales @ freiberginstruments.com

Product

SmartRAY2

Skip breadcrumb navigation Breadcrumb Freiberg Instruments Products Radiation Monitoring Systems SmartRAY2 SmartRAY2 High range dose rate meter Interested? Get in touch! Contact now Skip menu Quick navigation Features Contact Features & Benefits Probe use of a selected gamma ionization chamber suitable for its gamma sensitivity for the measurement of gamma dose rate and dose 10 decades measuring range for the gamma dose rate stainless steel housing for the gamma ionization chamber, suitable for an underwater use down to 40 m depth pluggable waterproof cable connection on the stainless-steel housing, mono-cable connection between stainless steel housing and cable drum possible use of ionization chambers with different gamma sensitivities for the shift of the 10-decades measuring range State-of-the-art electronics in operation proven SMC 2100 measuring technique with current-to-frequency converter, integrated in the SmartRAY2 housing SmartRAY2 with serial interface RS485 for a PC connection 7“ color display with touch functions, resolution 800x480 pixels integrated in the SmartRAY2 housing storage of the measured values on MicroSD card readout of the measured values via USB connection connections for relays, signal lights and external start signal output of the measured value as analog 0-20mA current signal mains or battery pack operation, accumulator charging at mains operation, energy management for battery pack control cable drum for probe connection on long cables up to 60 m Get in touch Do not hesitate to contact us – we are available to assist you with any inquiries or requests. Use our inquiry tool or reach out via email: sales @ freiberginstruments.com

Page

Software

Lexsyg Software LexStudio 2.0 - Operating software Modern, professionally designed user interfacensitivity: Based on user feedback a new graphical user interface which combines clear arrangement and usability is developed by Freiberg… Learn more LexEva - Evaluation software LexEva is a newly released evaluation software developed for analysis in luminescence research and dating. LexEva was adapted to the "Luminescence" package developed by the R. Luminescence… Learn more TLStudio - Operating & Evaluation software User account management system, Transperent workflow, Professionally designed user interface, Intelligent parameter selection, Live data visualization, Easy programming of individual and… Learn more OSLdosimetry OSLdosimetry is a user friendly operating software which allows OSL dose measurements as standard user or calibration and setting features for professionals (password protected). The… Learn more

Page

Software

Software PIDStudio PIDStudio is a cutting-edge, user-friendly software that is continuously updated and improved based on user feedback. It allows for easy handling and provides intuitive functionality. With… Learn more

Page

Software

MDP Software Software - PICTSStudio The PICTSStudio offers features for defect investigation like,Operation and configuration area, Results/charting, View of single transients and temperature dependent curves, Evaluation of… Learn more

Page

Software

HR-SPS Software Software - SPS Studio Learn more

Technology

Software - PICTSStudio

PICTSStudio user friendly and advanced software for defect investigations The PICTSStudio offers features for defect investigation like, Operation and configuration area Results/charting View of single transients and temperature dependent curves Evaluation of activation energy and capture cross sections via Arrhenius plot Get in touch Do not hesitate to contact us – we are available to assist you with any inquiries or requests. Use our inquiry tool or reach out via email: sales @ freiberginstruments.com

Technology

Software - SPS Studio

Software - SPS Studio Get in touch Do not hesitate to contact us – we are available to assist you with any inquiries or requests. Use our inquiry tool or reach out via email: sales @ freiberginstruments.com

Application

Solar Cell Classification

Solar Cell Classification The PIDcon enables quick, routine quality control of solar cell PID susceptibility, unaffected by the EVA foil and glass Potential Induced Degradation (PID) poses a significant reliability issue in PV power plants, making it essential to assess products for their susceptibility to PID. The PIDcon system enables manufacturers to test their products as early as possible in the production process, starting at the solar cell level, and to evaluate the encapsulation materials as well. This allows for independent investigation of the solar cell and its SiNx layer, separate from the effects of the EVA and glass. The type of PID considered here involves shunting of solar cells due to high-voltage stress-induced leakage currents (PID-s). To effectively classify solar cells, it is crucial to use sensitive EVA and glass materials so that the solar cell itself becomes the critical factor influencing the PID susceptibility of the entire stack. A lamination step can be added prior to measurement to enhance comparability with actual modules. The solar cells are connected using gold contact pins, which can be adjusted to fit the busbar design, even for island busbars. The PIDStudio software allows users to set pass/fail criteria for the test, suggesting defaults based on IEC standards and insights from Fraunhofer CSP scientists. Fig. 1: Solar cell with EVA foil and glass placed in a PIDcon Matching Products PID series PIDcon bifacial Quality Control Solution for Bifacial PERC/PERC+, HIT, Topcon, c-Si Solar Cells, Mini Modules, and More Learn more Get in touch Do not hesitate to contact us – we are available to assist you with any inquiries or requests. Use our inquiry tool or reach out via email: sales @ freiberginstruments.com