Found 271 results in 1 milliseconds.

Page

Aliquot preparation kit

Skip breadcrumb navigation Breadcrumb Freiberg Instruments Products Luminescence Dating and Dosimetry lexsygresearch Optional accessories Aliquot preparation kit Aliquot preparation kit for quick silicon stamping on hundreds of sample cups or discs Interested? Get in touch! Contact now Procuct-Sheet Our brand new Aliquot preparation kit includes a stamp and a template for quick silicon stamping on hundreds of sample cups or discs. Donwload Product-Sheet Manual_Aliquot_Preparation_Kit_03032015.pdf 619 KB

Page

Vacuum pump

Skip breadcrumb navigation Breadcrumb Freiberg Instruments Products Luminescence Dating and Dosimetry lexsygresearch Optional accessories Vacuum pump Vacuum pump To automatically evacuate the measurement chamber before creating a nitrogen atmosphere or for alpha irradiation Interested? Get in touch! Contact now Features Compact rotary vane pump Automatically controlled by the lexsyg device Low weight Low maintenance Includes all necessary seals, flanges and pipes

Page

LED head lamp

Skip breadcrumb navigation Breadcrumb Freiberg Instruments Products Luminescence Dating and Dosimetry lexsygresearch Optional accessories LED head lamp LED head lamp Red head lamp for sample treatment in dark rooms or luminescence labs Interested? Get in touch! Contact now 660 nm ± 15 nm Two intensities No side bands

Page

Spectrometry detection unit

Skip breadcrumb navigation Breadcrumb Freiberg Instruments Products Luminescence Dating and Dosimetry lexsygresearch Configuration options Spectrometry detection unit Spectrometry detection unit for IR and UV spectroscopy Interested? Get in touch! Contact now OE-CCD based high sensitivity spectrometry detection unit (Recommended for IR spectroscopy) fiber-coupled CCD based luminescence emission spectrometer TE-cooled (min. -80 °C) CCD-detector 200 – 1050 nm, 16 bit digitization easy change of gratings and wavelength re-calibration, one grating can be selected powerful spectrometry software integration into lexsyg measurement control software BU-CCD based high sensitivity spectrometry detection unit (Recommended for UV spectroscopy) 1024 x 255 Pixel, 26 μm back Illuminated BU 5 years guarantee of UltraVac vacuum sealing of CCD-chamber including software implementation high quality Non-Imaging spectrograph focal distance: 163 mm aperture ratio: 3.6 grate: 300 l/mm, Blaze 500 nm optical fiber: Custom fiber bundle UV-VIS, Overall length: 3 m +/-5 cm, Fiber count: 114 approx. adapter for manual gap and shutter flange with cylindrical lens for InGaAs-Detector variable gap for SR163: 10 μm-13 mm

Page

EMCCD

Skip breadcrumb navigation Breadcrumb Freiberg Instruments Products Luminescence Dating and Dosimetry lexsygresearch Configuration options EMCCD EMCCD Dose determination of single grains on multi grain aliquots by spatially resolved luminescence provided by a state-of-the-art electron multiplying CCD camera (EMCCD) Interested? Get in touch! Contact now Spatially Resolved Single Grain Analysis using EMCCD UV to NIR (200 – 1050 nm) image detection for spatially resolved / single-grain measurement operational at the TL/OSL or RF measurement position 512 x 512 pixel back-thinned, UV-coated EMCCD chip (electron multiplying – EM - technology), 16 bit resolution, frame – transfer format operates also in traditional CCD mode (low noise) max. frame rate: > 33 frames/second (full frame) gigabit Ethernet data interface high quantum efficiency from UV to NIR : approx. 50% @ UV Quartz OSL emission peak; approx. 85-90 % @ all VIS Quartz/Feldspar emission peaks; approx. 60% @ potassium feldspar NIR RF peak (865 nm) ~8 mm diameter sample is imaged on the camera chip (ca. 16 μm / pixel) incl. electromechanical shutter TE cooling min. -95 °C (-70 °C guaranteed for life), thermostatic precision ± 0.05°C integration into lexsyg measurement control software

Page

X-ray Fluorescence (XRF)

Skip breadcrumb navigation Breadcrumb Freiberg Instruments Products Luminescence Dating and Dosimetry lexsygresearch Configuration options X-ray Fluorescence (XRF) X-ray Fluorescence (XRF) This module allows an estimate of the mineral composition of feldspar samples. The relative proportion of K-/Na/-Ca-feldspar is estimated as well as the possible quartz contamination. Interested? Get in touch! Contact now This module allows an estimate of the mineral composition of feldspar samples. The relative proportion of K-/Na/-Ca-feldspar is estimated as well as the possible quartz contamination. The XRF unit consist of: Amptek X-123 complete spectrometer with SDD Complete X-ray spectrometer Amptek MINI-X USB controlled X-ray tube Software extension for XRF analysis: A special program for analyzing the XRF data for conversion of the result onto the ternary diagram of K-/Na/-Ca-feldspar and providing an estimate of quartz contamination. Reference samples for performing and maintaining the K-/Na/-Ca-feldspar calibration are included. Special sample cups: Sample cups specially made from molybdenum metal (200 pieces will be supplied) Note: XRF unit requires vacuum pump.

Page

Bleaching/Solar simulation unit

Skip breadcrumb navigation Breadcrumb Freiberg Instruments Products Luminescence Dating and Dosimetry lexsygresearch Configuration options Bleaching/Solar simulation unit Bleaching/Solar simulation unit for monochromatic sample irradiation or individually mixed for simulation of various bleaching conditions Interested? Get in touch! Contact now Features power LED-array based light irradiator, fan-cooled fully software controlled (power, irradiation time, mixing ratios - if applicable) within a measurement sequence the settings can be varied special optics for uniform irradiation power at the sample bleaching is possible at elevated temperatures LED-based bleaching/Solar simulation unit wavelengths: 365 nm, 462 nm, 523 nm, 590 nm, 625nm, 850 nm can be used for monochromatic sample irradiation or individually mixed for simulation of variousbleaching conditions typical maximum optical power at the sample: UV 365 nm : 65 mW RGB A 462 nm : 140 mW, 523 nm : 35 mW, 590 nm : 50 mW, 625 nm : 85 mW; IR 850 nm: 170 mW power regulation loop for each light channel display of bleaching light spectrum

Page

Sample camera

Skip breadcrumb navigation Breadcrumb Freiberg Instruments Products Luminescence Dating and Dosimetry lexsygresearch Configuration options Sample camera Sample camera The sample camera is designed to automatically record the appearance of the sample after luminescence measurements. Interested? Get in touch! Contact now The sample camera is designed to automatically record the appearance of the sample after luminescence measurements. For example: Visual inspection after luminescence data collection Use of image analysis for determining e.g. number of grains, coverage area, grain size distribution, color distribution The camera is mounted in a mechanical fixture that is vacuum tight, light tight and holds a diffuse light illumination system to assure proper white light illumination of the sample that is photographed. Technical details of the camera: TheImagingSource 1/2.5 “Micron CMOS 5Mp camera or similar camera (example: DFM 72BUC02-ML) Computar 3Mp f=25mm lens

Page

Ultra-fast pulsing (< 10 ns)

Skip breadcrumb navigation Breadcrumb Freiberg Instruments Products Luminescence Dating and Dosimetry lexsygresearch Configuration options Ultra-fast pulsing (< 10 ns) Ultra-fast pulsing (< 10 ns) Time Resolved Luminescence Interested? Get in touch! Contact now Module for fundamental studies on luminescence life-times and for separation of luminescence signals of different life-times by pulsed stimulation. Laser diode specifications: Rise/fall time: < 10 ns ON-Time: 50 ns to continuous wave Transient detection system: Time steps: 2.5 ns to 1 s Time point accuracy: < 50 ps Choice of logarithmic time scale over 7 decades (possibility of measurement of extremely short and extremely long time transients at a time) Measurement system exhibits no limitation in counting rate below 150 MHz

Page

Sample cups/discs

Skip breadcrumb navigation Breadcrumb Freiberg Instruments Products Luminescence Dating and Dosimetry lexsygresearch Optional accessories Sample cups/discs Sample cups/discs Excellent thermal conductivity provided by professionally manufactured sample cups made of stainless steel, aluminum or nickel Interested? Get in touch! Contact now Sample cups/discs are designed to provide excellent thermal conductivity. They are cleaned and vacuum sealed (20 pcs per/package) separately. Stainless steel VA 1.4301 most popular, for standard application maximum temperature: 710 °C Aluminum AlMg 3 low cost maximum temperature: 500 °C Nickel Ni 99.2 for experimental work low background measurements